Search results for: 'gf pp pressure system'
Products
- Pressure rating: 10 bar water / 5 bar gas
- Pressure rating: 10 bar water / 5 bar gas
- 16 bar Water
- With integral pipe fixation
- 4 mm pin connectors
- Limited path fusion indicators
- Delivered as a kit. Further combinations: modular system with threaded adapter and (150 228-1) reductions
- Incl. flat gasket for water applications (KTW / WRAS approved)
- 16 bar Water
- With integral pipe fixation
- 4 mm pin connectors
- Limited path fusion indicators
- Delivered as a kit. Further combinations: modular system with threaded adapter and (150 228-1) reductions
- Incl. flat gasket for water applications (KTW / WRAS approved)
- Pressure rating: 16 bar water / 10 bar gas
- Pressure rating: 16 bar water / 10 bar gas
- Pressure rating: 16 bar water / 10 bar gas
- Pressure rating: 16 bar water / 10 bar gas
- Pressure rating: 16 bar water / 10 bar gas
- FM 1613 approved - 15 bar
- Pressure rating: 16 bar water / 10 bar gas
- FM 1613 approved - 15 bar
- 10 bar Gas / 16 bar Water
- Branch Saddle installation only with installation set Topload TL225 (799.300.807)
- Angle adaptors (799.350.340) for fusion cable required
- 4 mm pin connectors
- Limited path fusion indicators
- Spigot outlet for butt- and electrofusion
- Full pressure applicable - no derating factor
- With integrated pressure test port for test cap (799.199.287)
- 10 bar Gas / 16 bar Water
- Branch Saddle installation only with installation set Topload TL225 (799.300.807)
- Angle adaptors (799.350.340) for fusion cable required
- 4 mm pin connectors
- Limited path fusion indicators
- Spigot outlet for butt- and electrofusion
- Full pressure applicable - no derating factor
- With integrated pressure test port for test cap (799.199.287)
- PE 100 SDR 11 (ISO S5)
- 10 bar Gas / 16 bar Water
- With integral pipe fixation
- 4 mm pin connectors
- Limited path fusion indicators
- Delivered as akit. Further combinations: modular system with threaded adapter and (150 228-1) reductions
- PE 100 SDR 11 (ISO S5)
- 10 bar Gas / 16 bar Water
- With integral pipe fixation
- 4 mm pin connectors
- Limited path fusion indicators
- Delivered as akit. Further combinations: modular system with threaded adapter and (150 228-1) reductions
- PE 100 SDR 11 (ISO S5)
- 10 bar Gas / 16 bar Water
- With integral pipe fixation
- 4 mm pin connectors
- Limited path fusion indicators
- Delivered as akit. Further combinations: modular system with threaded adapter and (150 228-1) reductions
- PE 100 SDR 11 (ISO S5)
- 10 bar Gas / 16 bar Water
- With integral pipe fixation
- 4 mm pin connectors
- Limited path fusion indicators
- Delivered as akit. Further combinations: modular system with threaded adapter and (150 228-1) reductions
NBR = Nitrile rubberhardness approx. 80° Shore
For all metric GF Flange Adaptors
Rubber-steel body combined with rubber profile cord ring up to d630
Rubber-steel body ideal for big "dimensions (d710 - d1000)
Approved acc. to DVGW standard DIN EN 682 for gas
D corresponds to the centring at the inner diameter of the screw crown
NBR = Nitrile rubberhardness approx. 80° Shore
For all metric GF Flange Adaptors
Rubber-steel body combined with rubber profile cord ring up to d630
Rubber-steel body ideal for big "dimensions (d710 - d1000)
Approved acc. to DVGW standard DIN EN 682 for gas
D corresponds to the centring at the inner diameter of the screw crown
NBR = Nitrile rubberhardness approx. 80° Shore
For all metric GF Flange Adaptors
Rubber-steel body combined with rubber profile cord ring up to d630
Rubber-steel body ideal for big "dimensions (d710 - d1000)
Approved acc. to DVGW standard DIN EN 682 for gas
D corresponds to the centring at the inner diameter of the screw crown
NBR = Nitrile rubberhardness approx. 80° Shore
For all metric GF Flange Adaptors
Rubber-steel body combined with rubber profile cord ring up to d630
Rubber-steel body ideal for big "dimensions (d710 - d1000)
Approved acc. to DVGW standard DIN EN 682 for gas
D corresponds to the centring at the inner diameter of the screw crown
- For IR, butt and electrofusion welding according to DVS 2207
- Type A: without chamfer
- Type B: with chamfer
- Suitable for plastic butterfly valves type 567/578/565 up to DN250. ecoFit adapter SDR11 required for DN350 and above
- Suitable for metal butterfly valves type 038/039/044/065 up to DN250. ecoFit adapter SDR11 is required for DN350 and above
- Profile seal: d20-d800 NBR, EPDM, FKM
- Flat gasket: d20-d315 EPDM, FKM
- Pressure rating: 16 bar water / 10 bar gas
- Please refer to the Online Tool: Perfect Flange Connection - GF Piping Systems (gfps.com)
- For IR, butt and electrofusion welding according to DVS 2207
- Type A: without chamfer
- Type B: with chamfer
- Suitable for plastic butterfly valves type 567/578/565 up to DN250. ecoFit adapter SDR11 required for DN350 and above
- Suitable for metal butterfly valves type 038/039/044/065 up to DN250. ecoFit adapter SDR11 is required for DN350 and above
- Profile seal: d20-d800 NBR, EPDM, FKM
- Flat gasket: d20-d315 EPDM, FKM
- Pressure rating: 16 bar water / 10 bar gas
- Please refer to the Online Tool: Perfect Flange Connection - GF Piping Systems (gfps.com)
- For IR, butt and electrofusion welding according to DVS 2207
- Type A: without chamfer
- Type B: with chamfer
- Suitable for plastic butterfly valves type 567/578/565 up to DN250. ecoFit adapter SDR11 required for DN350 and above
- Suitable for metal butterfly valves type 038/039/044/065 up to DN250. ecoFit adapter SDR11 is required for DN350 and above
- Profile seal: d20-d800 NBR, EPDM, FKM
- Flat gasket: d20-d315 EPDM, FKM
- Pressure rating: 16 bar water / 10 bar gas
- Please refer to the Online Tool: Perfect Flange Connection - GF Piping Systems (gfps.com)
- For IR, butt and electrofusion welding according to DVS 2207
- Type A: without chamfer
- Type B: with chamfer
- Suitable for plastic butterfly valves type 567/578/565 up to DN250. ecoFit adapter SDR11 required for DN350 and above
- Suitable for metal butterfly valves type 038/039/044/065 up to DN250. ecoFit adapter SDR11 is required for DN350 and above
- Profile seal: d20-d800 NBR, EPDM, FKM
- Flat gasket: d20-d315 EPDM, FKM
- Pressure rating: 16 bar water / 10 bar gas
- Please refer to the Online Tool: Perfect Flange Connection - GF Piping Systems (gfps.com)